Attention:On the usage of a screened cable the connection cable is allowed to be max. 50 m long.
Housing material | Plastic |
Ambient temperature | 0 … 50 °C |
Degree of protection | IP65 |
Mounting method | Surface |
Connection | M12 plug, 8-pin, axial connection |
Electrical connection ratings
Operating voltage DC | 20 … 28 V DC |
Current consumption | 80 … 100 mA Without load |
Switching current | -30 … +30 mA Per output |
Type of output | Push-Pull |
Resistance | 4,5 k? Input resistance |
Output voltage | |
min.Ub — 2 V DC For HIGH level | |
max.2 V DC For LOW level | |
Input voltage | |
max.2 V DC SKIP input LOW level | |
min.15 V DC SKIP input HIGH level |
Interface, bus
Data interface | 4 bit binary coded + strobe |
In combination with Data carrier CIS3AP50X50SH16YSNOU, CIS3AP50X50SH16YSNOPMechanical values and environment
Approach speed | |
At 25°C, read distance s=20mm, center offset m=0mm for 4 hexadecimal digits | max.13,8 m/min |
Operating distance
Read distance | |
At 25°C, center offset m=0mm | 12 … 20 … 28 mm |
Center offset | |
At 25°C, read distance s=20mm | -13 … 13 mm |