Mounting instructionsOn mounting the read head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read head is observed.
Attention:On the usage of a screened cable the connection cable is allowed to be max. 50 m long.
Housing material | CuZn, nickel-plated |
Ambient temperature | 0 … 50 °C |
Degree of protection | IP67 |
Mounting method | Surface |
Connection | M12 plug, 8-pin, axial connection |
Electrical connection ratings
Operating voltage DC | 20 … 28 V DC |
Current consumption | |
Without load | 65 … 100 mA |
Switching current | -30 … +30 mA Per output |
Type of output | Push-Pull |
Resistance | 4,5 k? Input resistance |
Output voltage | |
min.Ub — 3 V DC For HIGH level | |
max.2 V DC For LOW level | |
Input voltage | |
max.2 V DC SKIP input LOW level | |
min.15 V DC SKIP input HIGH level | |
LED indicator | Yellow: Data carrier active |
Interface, bus
Data interface | 4 bit binary coded + strobe |
In combination with Data carrier CIS3P16D08KH16YSNOU, CIS3P16D08KH16YSNOPMechanical values and environment
Approach speed | |
At 25°C, read distance s=5mm, center offset=0mm in Y direction, for 4 hexadecimal | max.19,2 m/min |
Operating distance
Read distance | 5 mm 0 … 14 mm |
Center offset | |
At 25°C, read distance s=5mm, in Y direction | -6 … 6 mm |
At 25°C, read distance s=5mm, in X direction | -18 … 18 mm |
In combination with Data carrier CIS3P35X16SH16YHNOP, CIS3P35X16SH16YHNOU, CIS3P35X16SH16YVNOP, CIS3P35X16SH16YVNOUMechanical values and environment
Approach speed | |
At 21°C, read distance s=7mm, center offset=0mm in Y direction, for 4 hexadecimal | max.24,6 m/min |
Operating distance
Read distance | |
At 21°C | 7 mm 0 … 18 mm |
Center offset | |
At 21°C, read distance s=7mm,in X direction | -23 … 23 mm |
At 21°C, read distance s=7mm,in Y direction | -8 … 8 mm |