Attention:
- The connection cable to the control system is allowed to be max. 15 m long.
- On the usage of a screened cable the connection cable to the read head is allowed to be max. 15 m long.
- It is only ever possible to connect 1 read head per interface adapter.
Housing material | PA6.6 gray |
Ambient temperature | 0 … 55 °C |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Number of read heads | max.1 |
Connection | Plug-in screw terminal |
Electrical connection ratings
Operating voltage DC | 20 … 24 … 28 V DC |
Current consumption | |
Without load | 65 mA max.100 mA |
LED indicator | |
Green | STATE LED operational |
Yellow | ACTIVE LED data carrier active |
Switching voltage | |
Ub-3 … Ub V High signal (A,B,C,D,Strobe) | |
0 … 2 V Low signal (A,B,C,D,Strobe) | |
Switching current | |
Per output | — 30 … +30 mA |
Type of output | Push-Pull |
Connection cross-section | 0,14 … 2,5 mm? |
Resistance | 4,5 k? For inputs (Reset,Skip) |
Input voltage | |
15 … Ub V DC High signal (Reset,Skip) | |
0 … 2 V DC Low signal (Reset,Skip) |
Interface, bus
Data interface | 4 bit binary coded + strobe |
In combination with Read head CIT3ASX1N12ST and Data carrier CIS3AP10D05KH01K, CIS3AP10D05KH01K-POperating distance
Read distance | |
With center offset m=0 | 0 … 3 … 6,5 mm |
0 … 3 … 5 mm | |
0 … 3 … 6 mm | |
Center offset | |
Read distance s = 3 mm | -2,5 … 2,5 mm |