Euchner ANWPG ELECTRONIC KEY MANAGER (Order no. 093322)
- Software for key management
- Client/server architecture, full network support
- Access to key database and key database export/import in csv format
- Forms and databases prepared using the demo version, light version or single-user version can continue to be used with the full version
- Includes EKM ActiveX® module for interfacing the EKM database to any user program with ActiveX® support (e.g. for visualization)
- Includes EKM ActiveX® module manual – order no. 093650 on CD
- Includes additional documentation EKM (CRC definition) – order no. 093653 on CD
Euchner ANWPG ELECTRONIC KEY MANAGER DEMO (Order no. 093320)
- Software for key management
- Only local EKM client, no network support
- Access to key database and key database export/import in csv format
- Limited to 10 weeks runtime
Euchner ANWPG ELECTRONIC KEY MANAGER EINZEL (Order no. 098578)
- Software for key management
- Only local EKM client, no network support
- Access to key database and key database export/import in csv format
- Forms and databases prepared using the demo version or light version can continue to be used with the full version
- Includes additional documentation EKM (CRC definition) – order no. 093653 on CD
Euchner ANWPG ELECTRONIC KEY MANAGER LIGHT (Order no. 111410)
- Software for setting key parameters
- Only local EKM client, no network support
- No access to key database and no key database export/import
Euchner ANWPG TRANSPONDER CODING VERKAUF (Order no. 067190)
- Software for reading and writing CIS data carriers or EKS Electronic-Keys
Euchner CEM-A-LE05H-S2-104606 (Order no. 104606)
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- Adjustable adhesive force
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included
Euchner CEM-A-LE05K-S2 (Order no. 094800)
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- With remanence
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included
Euchner CEM-A-LE05K-S2-P-158763 (Order no. 158763)
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- With permanent magnet 30 N
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included
Euchner CEM-A-LE05R-S2 (Order no. 095792)
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- Without remanence
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included
Euchner CEM-A-LH10K-S3 (Order no. 095170)
- Read head with guard locking without guard lock monitoring
- Locking force 1000 N
- With remanence
- Up to category 4 according to EN ISO 13849-1
Euchner CEM-A-LH10R-S3 (Order no. 095793)
- Read head with guard locking without guard lock monitoring
- Locking force 1000 N
- Without remanence
- Up to category 4 according to EN ISO 13849-1
Euchner CEM-A-ME05K-S1 (Order no. 109755)
- Electromagnet for locking access doors
- Locking force 650 N
- With remanence
- No guard lock monitoring, no monitoring of the door position
- Connection using an M8 plug connector
Euchner CEM-I2-AR-M-C40-SH-113739 (Order no. 113739)
- Safety switches with guard locking for process protection and integrated evaluation electronics
- Solenoid with locking force 600 N
- Adhesive-force adjustment in 3 levels
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1 for door position monitoring
- With plug connector M23
- Multicode
- Door monitoring output
Euchner CEM-I2-AR-U-C40-SH-124937 (Order no. 124937)
- Safety switches with guard locking for process protection and integrated evaluation electronics
- Solenoid with locking force 600 N
- Adhesive-force adjustment in 3 levels
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1 for door position monitoring
- With plug connector M23
- Unicode
- Door monitoring output
Euchner CEM-I2-AY-U-C40-SA-128103 (Order no. 128103)
- Safety switches with guard locking for process protection and integrated evaluation electronics
- Solenoid with locking force 600 N
- Adhesive-force adjustment in 3 levels
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1 for door position monitoring
- With plug connector M12
- Unicode
- Door monitoring output
Euchner CEM-M2-C60-PZ-SE-161320 (Order no. 161320)
- Magnetic guard locking for process protection
- Guard locking solenoid with locking force of 650 N
- Function expansion for safety switch CES-C04 / CES-C07
- Flexibility through a large selection of safety switches
- Maximum safety level PL e / category 4 for detection of the door position
- Transponder coding prevents high level of protection against tampering
- Simple connection of the solenoid using M12 plug connector, 5-pin
- Yellow LED to indicate voltage at the solenoid
- Nickel-plated solenoid surface with high corrosion resistance
- Integrated permanent magnet, 30 N adhesive force
Euchner CES-A-BBA-EX (Order no. 098158)
- ATEX version
- Suitable for usage in zone 2 and 22 (gases and dusts)
- Cube-shaped design 42 x 25 mm
Euchner CES-A-BBN-C04-EX-137527 (Order no. 137527)
- ATEX version
- Suitable for usage in zone 2 and 22 (gases and dusts)
- Cube-shaped design 42 x 25 mm
- Two safety screws M4x20 and rubber support included
Euchner CES-A-BPA-EX (Order no. 102125)
- ATEX version
- Suitable for usage in zone 2 and 22 (gases and dusts)
- Cube-shaped design 40 x 40 mm
Euchner CES-A-C5E-01 (Order no. 077750)
- Safety switch with integrated evaluation electronics
- Possible to switch pulsed signals
- 2 safety outputs (semiconductor outputs)
- Category 3/PL e according to EN ISO 13849-1
- Unicode
Euchner CES-A-C5H-01 (Order no. 091458)
- Safety switch with integrated evaluation electronics
- Possible to switch pulsed signals
- 2 safety outputs (semiconductor outputs)
- Category 4/PL e according to EN ISO 13849-1
- Unicode
Euchner CES-A-C5H-01-EX (Order no. 097945)
- ATEX version
- With protective plate
- Suitable for use in zones 2 and 22 (gases and dusts)
- Safety switches as interlocking device of type 4
- Safety switch with integrated evaluation electronics
- Possible to switch pulsed signals
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
Euchner CES-A-LCA-10V (Order no. 088785)
- Cube-shaped design 42 x 25 mm
- Hard-wired encapsulated cable made of PVC
- Cable length 10 m
- Two safety screws M4x14 included
Euchner CES-A-LMN-SC (Order no. 077790)
- Cylindrical design M12
- M8 plug connector
Euchner CES-A-LNA-05P (Order no. 077806)
- Cube-shaped design 42 x 25 mm
- Hard-wired encapsulated cable made of PUR
- Cable length 5 m
- Two safety screws M4x14 included
Euchner CES-A-LNA-05V (Order no. 071845)
- Cube-shaped design 42 x 25 mm
- Hard-wired encapsulated cable made of PVC
- Cable length 5 m
- Two safety screws M4x14 included
Euchner CES-A-LNA-10P (Order no. 077807)
- Cube-shaped design 42 x 25 mm
- Hard-wired encapsulated cable made of PUR
- Cable length 10 m
- Two safety screws M4x14 included
Euchner CES-A-LNA-10V (Order no. 071846)
- Cube-shaped design 42 x 25 mm
- Hard-wired encapsulated cable made of PVC
- Cable length 10 m
- Two safety screws M4x14 included
Euchner CES-A-LNA-15P (Order no. 084682)
- Cube-shaped design 42 x 25 mm
- Hard-wired encapsulated cable made of PUR
- Cable length 15 m
- Two safety screws M4x14 included
Euchner CES-A-LNA-15V (Order no. 071847)
- Cube-shaped design 42 x 25 mm
- Hard-wired encapsulated cable made of PVC
- Cable length 15 m
- Two safety screws M4x14 included
Euchner CES-A-LNA-25V (Order no. 071975)
- Cube-shaped design 42 x 25 mm
- Hard-wired encapsulated cable made of PVC
- Cable length 25 m
- Two safety screws M4x14 included
Euchner CES-A-LNA-SC (Order no. 077715)
- Cube-shaped design 42 x 25 mm
- With plug connector M8
- Two safety screws M4x14 included
Euchner CES-A-LNN-05V-106602 (Order no. 106602)
- Cube-shaped design 42 x 25 mm
- Attachment compatible with series CES-A-LNA/LCA
- LED for the indication of the door position
- Hard-wired encapsulated cable, PVC
- Cable length 5 m
Euchner CES-A-LNN-10V-113294 (Order no. 113294)
- Cube-shaped design 42 x 25 mm
- Attachment compatible with series CES-A-LNA/LCA
- LED for the indication of the door position
- Hard-wired encapsulated cable, PVC
- Cable length 10 m
Euchner CES-A-LNN-25V-115107 (Order no. 115107)
- Cube-shaped design 42 x 25 mm
- Attachment compatible with series CES-A-LNA/LCA
- LED for the indication of the door position
- Hard-wired encapsulated cable, PVC
- Cable length 25 m
Euchner CES-A-LNN-SC-106601 (Order no. 106601)
- Cube-shaped design 42 x 25 mm
- Attachment compatible with series CES-A-LNA/LCA
- LED for the indication of the door position
- With plug connector M8