Expansion device with two control inputs, two safe outputs and two monitoring outputs.
Dimensions | 108 x 22.5 x 114.5 |
Material | |
Housing | Polyamide |
Ambient temperature | -10 … +55 °C |
Atmospheric humidity | 10 … 95 % rH |
Degree of protection | IP20 |
Mounting method | Mounting rail 35mm |
Connection | Plug-in screw terminal |
Cable length | max.100 m 1mm2.’> |
Status (can be programmed via software) | |
Number of monitoring outputs | 2 |
External relay monitoring (EDM), automatic, manual operation | |
Number of inputs | 2 |
For node selection | |
Number of inputs | 2 |
Safety outputs OSSD1, OSSD2 | |
Number of safety outputs | 2 |
Electrical connection ratings
Operating voltage DC | |
UB | 24 V DC -20% … +20% PELV |
Overvoltage category according to IEC EN 60664-1 | II |
Degree of contamination according to EN 60664-1 | 2 |
Connection cross-section | 0,5 … 2,5 mm? Screw terminal |
Delay time | 0,0106 … 0,0546 s + filter time |
Power consumption | max.3 W |
Status (can be programmed via software) | |
Type of output | Semiconductor outputs, p-switching |
Output current | max.100 mA |
External relay monitoring (EDM), automatic, manual operation | |
Type of input | Semiconductor inputs, p-switching |
For node selection | |
Type of input | Semiconductor inputs, p-switching |
Safety outputs OSSD1, OSSD2 | |
Test pulses | 0,1 ms |
Inductive load | max.30 mH |
Capacitive load | max.0,82 ?F |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH | UB-0,75 … UB V DC |
LOW | 0 … 2 V DC |
Output current | — … 400 mA |
Reliability values according to EN ISO 13849-1
ESPE type | 4 |
Performance Level | PL e |
Category | 4 |
PFHD | 4.09E-09 1/h |
SIL CL | 3 |
Mission time | 20 y |