Guard locking type
MGB-L1… | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
Door stopA mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicatorThe LED indicator indicates all important system and status information.
Monitoring outputs
OD | ON when the door is closed |
OT | Bolt tongue inserted into the evaluation module |
OI | Diagnostics; there is a fault |
NoticeThe interlocking module, handle module and the escape release are each pre-assembled on a mounting plate.
Escape release
The escape release enables people accidentally shut in to open the guard locked door from the danger zone.
Dimension drawing
Dimension drawing
Dimension drawing
Plug connector RC18
MGB: The MGB-System in use
MGB: MGB Impact test
MGB: Mounting left door, with escape release
Mounting left door, without escape release
Mounting right door, without escape release
MGB: Changing series wiring (AR) to single wiring (AP)
MGB: Deactivating guard lock monitor
MGB: Activating guard lock monitor
MGB: Activating release monitoring
MGB: Change color-lens push button
Dimension drawingDimension drawingDimension drawingPlug connector RC18
Technical data
Locking module MGB-L1-APA-AA1A2-S1-L-112599 (Order no. 112599)
Mechanical values and environment
Housing material | Reinforced plastic; die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,35 kg |
Ambient temperature | |
At UB = 24V DC | -20 … 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Electrical connection ratings
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% … 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% … 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 … 1 V DC |
UFO1A /UFO1B HIGH | UB-2V … UB V DC |
Output current | |
Per safety output FO1A / FO1B | 1 … 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V … UA V DC |
Output current | max.50 mA |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Other
Additional feature | Mounting plate |
Product version number | V3.0.3 |
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Mission time | 20 y |
Handle module MGB-H-AA1A6-L-111839 (Order no. 111839)
Mechanical values and environment
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 … 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN left |
Other
Additional feature | With mounting plate and automatic lockout mechanism |
Product version number | V3.0.0 |
Escape release MGB-E-A2-106051 (Order no. 106051)
Mechanical values and environment
Housing material | Die-cast zinc/stainless steel powder-coated |
Weight | |
Net | 1,05 kg |
Ambient temperature | -20 … 55 °C |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Other
Additional feature | With mounting plate |
Product version number | V2.0.0 |
Components
112599
Locking module MGB-L1-APA-AA1A2-S1-L-112599
- Guard locking with guard lock monitoring
- With plug connector RC18
- Mounted on mounting plates
- Unicode
111839
Handle module MGB-H-AA1A6-L-111839
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate
106051
Escape release MGB-E-A2-106051
- Escape release out of the danger area
- Mounted on mounting plate
- With red handle
- 118 mm long