Dimension drawing
Wiring diagram
MGB: The MGB-System in use
MGB: MGB Impact test
MGB: Mounting left door, with escape release
Mounting left door, without escape release
Mounting right door, without escape release
MGB: Deactivating guard lock monitor
MGB: Activating guard lock monitor
MGB: Activating release monitoring
MGB: Change color-lens push button
Dimension drawingWiring diagram
Technical dataApprovals
Mechanical values and environment
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 3,1 kg |
Ambient temperature | |
At UB = 24V DC | -20 … 55 °C |
Degree of protection | IP54 |
Resilience to vibration | In accordance with EN 60947-5-3 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Reaction time | |
Emergency stop / machine stop | max.100 ms Switch-off time |
Door position | max.250 ms Switch-off time |
Bolt position | max.250 ms Switch-off time |
Guard locking | max.250 ms Switch-off time |
Switching frequency | 0,25 Hz |
Connection | |
M12 Power, A-coded | |
M12 Power, A-coded | |
Ethernet/IP cable, Cat. 5e min. | M12 D-coded, screened |
M12 D-coded, screened | |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Electrical connection ratings
Current consumption | max.500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Maximum feed-in current in the connection block | |
X1, X2 | max.4000 mA |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
Ethernet | Ethernet/IP cable, Cat. 5e min. |
Safety class | III |
Transponder coding | Unicode |
Power supply X1 | |
Operating voltage DC | |
L1 | 24 V DC -15% … 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% … +10% |
Fusing | |
external | min.1 A Slow blow |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% … 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% … +10% |
Work area
Assured switch-off distance Sar | max.65 mm |
Interface, bus
Data interface | |
Data protocol | |
Bus protocol | Ethernet/IP |
Safety protocol | CIP Safety |
Controls and indicators
Belegungsschema | B1 |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Emergency stop illuminated |
Einlegeschild | |
Extras | With adhesive ring |
Farbe | |
Schaltelement | 2 pos. driven NC |
Position 90 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Position 91 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Position 92 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Other
Additional feature | |
Incl. cover set ID. No. 120344 | |
Incl. cover set ID. No. 120377 | |
Product version number | V1.2 |
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.37 x 10-9 |
Diagnostic Coverage (DC) | 99 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.91 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0.1 x 106 |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.05 x 10-9 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Mission time | 20 |