Notes
- Output A05 suitable for Siemens control systems with RS422 input
Dimension drawing
Wiring diagram
Ausgangssignale
Hand-held pendant stations and hand wheels
Dimension drawingWiring diagramAusgangssignale
Technical dataApprovals
Mechanical values and environment
Material | Aluminum |
Weight | |
Net | 0.095 |
Ambient temperature | 0 … 50 °C |
Atmospheric humidity | |
(condensation not permissible) | 0.8 |
Degree of protection | |
IEC 529 | IP65 |
acc. to NEMA 250 | 250-12 |
Resilience to vibration | |
Vibration (3 axes) | DIN/IEC 68-2-6 |
Shock (3 axes) | DIN/IEC 68-2-27 |
Tightening torque | max.0,25 Nm |
Connection | Screw terminal |
Detent positions per revolution | 100 |
Electrical connection ratings
Operating voltage DC | 5 V DC -5% … 5% |
Current consumption | |
Without load | max.80 mA |
EMC protection requirements | |
Acc. to CE | EN 61000-6-2, EN 61000-6-4 |
Type of output | RS422 |
Connection cross-section | 0,08 … 1,5 mm? |
Connection cross-section, AWG | 28 … 16 AWG |
Pulses per revolution | 2×100 |
Output voltage | In accordance with RS422A |
Other
Detent mechanism | Magnetic |