Relay outputsThe outputs are electrically decoupled and of redundant design.
Connection
- Two buttons each with one normally closed contact and one normally open contact that are monitored for simultaneity according to EN 574. In this way a high level of protection against tampering is provided.
- Short circuit monitoring to detect short circuits between the connection cables and to shut down the outputs or prevent relay starting if necessary
- Earth fault/ground fault monitoring to detect short circuits between the connection cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Connection optionsBy using suitable wiring the following function can be selected:
- Monitoring of downstream relays or contactors
Dimension drawing
Wiring diagram
Dimension drawingWiring diagram
Technical dataApprovals
Mechanical values and environment
Housing material | Polyamide PA6.6 |
Weight | |
Net | 0,23 kg |
Ambient temperature | |
At UB = 115/230V AC | -15 … 40 °C |
Degree of protection | IP20 |
Mechanical life | |
operating cycles | 10 x 106 |
Contact material | AgSnO2 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals |
Length of control cable | |
With conductor cross-section 0.75mm2 | 1000 m |
Safety contacts 13/14, 23/24 | |
Number of safety contacts | 2 |
Electrical connection ratings
Operating voltage | |
AC | 115 V -10% … +10% |
Power consumption (apparent power) | |
At 230 V AC | 3,7 VA |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | |
Leakage path/air gaps | 4 kV |
Overvoltage category according to IEC EN 60664-1 | 3 |
Rated supply frequency | 50 … 60 Hz |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 … 2,5 mm? Connection terminal (size) |
Test voltage | |
Control system/contacts | 2,5 kV |
Control voltage | |
On S12-S13 and on S22 and S23 | 24 V |
Control current | |
Both push buttons | 40 mA 2x |
LED indicator | 2 status displays (green) for relays K1 and K2 |
Safety contacts 13/14, 23/24 | |
Type of output | |
NO | Relay contacts, floating, positively driven (redundant) |
Switching voltage | |
AC | max.250 V |
DC | max.24 V |
Switching current | min.20 mA at 24V |
Fusing | |
External contact fuses (safety circuit) according to IEC 60269-1 | 10A gG (T6A / F8A) |
Utilization category according to EN 60947-5-1 | |
AC-15 | 3A, 250V |
DC-13 | 3A, 24V |
AC-12 | 6A ohmic load, 250V |
DC-12 | 6A ohmic load, 24V |
Breaking capacity according to UL | 6A 250V AC / 2A 24V DC |
Delay time | |
After operation of the push buttons | max.0,02 s Response delay time |
Release time | max.0,02 s |
Synchronization time | max.0,5 s |
Other
In compliance with | EN 60439-1: 1999 + A1: 2004; EN 60947-1: 2007; EN 60947-5-1: 2004; EN 60947-7-1: 2002; EN 61000-6-2: 2005; EN 61000-6-3: 2007; EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 60204-1: 2007; EN 574: 1996 + A1: 2008 |
Reliability values according to EN ISO 13849-1
Performance Level | PL e |
Category | 4 |
PFHD | 1.2 x 10-8 |
Number of switching cycles | |
? 1 A at 24 V DC | max.100000 1/Jahr |
? 0.1 A at 24 V DC | max.400000 1/Jahr |
? 3 A at 24 V DC | max.22500 1/Jahr |
Mission time | 20 y |