Dimension drawing
Wiring diagram
EKS FSA — Selection of safe operation mode with touch panels up to PL e
Dimension drawingWiring diagram
Technical dataApprovals
Mechanical values and environment
Housing material | PA6-GF30 gray |
Ambient temperature | 0 … 55 °C |
Degree of protection | IP67 in installed state (only access side) |
Mounting cut-out according to DIN 43700 | 33 x 68 mm |
Installation orientation | On the front |
PROFINET interface | |
Connection | RJ-45 socket |
Electrical connection ratings
LED indicator | |
Green | Operational |
Yellow | Key in operating distance |
Red | Fault |
PROFINET interface | |
Connecting cable | |
Min.2×2 twisted pair copper cable shielded, min. Cat. 5 | |
Star topology wiring | |
Power supply | |
Operating voltage DC | 20 … 24 … 28 V DC |
Current consumption | max.150 mA |
Parameters for the outputs LA and LB | |
Switching voltage | 24 … 30 V |
Switching current | 1 … 10 … 50 mA With short circuit protection max. 100 times |
Utilization category according to EN 60947-5-1 | |
AC-15 | 24V 50mA |
AC-12 | 24V 50mA |
DC-12 | 24V 50mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 50mA |
Connection cross-section | 0,14 … 1,5 mm? Screw terminal 2×2-pole |
Discrepancy time | 200 ms Difference time between outputs (LB first) |
Interface, bus
PROFINET interface | |
Data protocol | PROFINET |
Data rate | 10/100 Mbit/s |
Data interface | Ethernet (IEEE 802.3) |
Other
Parameters for the outputs LA and LB | |
Additional feature | |
35 Resistance in switched-on state in Ohm | |
max.1 Capacitive load per output in µF |