Switching elementReed contact, 1 NO contact
Never switch incandescent lamps. Not even for test purposes. Single hole fixing limit switches must not be used as an end stop.
Dimension drawing
Wiring diagram
Wiring diagram
Dimension drawingWiring diagramWiring diagram
Technical dataApprovals
Mechanical values and environment
Design | Thread M12 x 1 |
Housing material | |
Threaded section | Stainless steel |
Sleeve | Brass, nickel-plated |
Ambient temperature | -25 … 80 °C |
Degree of protection | IP67 |
Mechanical life | 5 x 106 |
Contact material | Rhodium |
Switching principle | Reed contact |
Repeat accuracy (absolute) | ±0,01 mm |
Installation orientation | Any |
Number of NO contacts | 1 |
Connection | Plug connector |
Approach speed | 0,01 … 8 m/min |
Actuating element | Domed plunger |
Actuating force | |
Approx. | 16 N |
Electrical connection ratings
Utilization category according to EN 60947-5-1 | |
DC-13 | 0.3A 24V |
AC-12 | 0.3A 30V |
Short circuit protection according to IEC 60269-1 | 0.4A gG |
Rated insulation voltage Ui | 50 V |
Switching voltage | |
min. | 1 V |
Switching current | |
Min. at 24V | 1 mA |
Other
C number | |
C2083 | Contact travel 8mm |