Approach direction
Horizontal
Can be adjusted in 90° steps
Guard locking type
CTP?L2 | Guard locking actuated by power-ON applied and spring released (open-circuit current principle). |
Control of the guard locking solenoid
The guard locking solenoid can be controlled via AS-Interface bus bit D0 or via the auxiliary power.
AS-Interface inputs
D0, D1 | Door monitoring |
D2, D3 | Guard lock monitoring |
Evaluation is performed via a safety monitor.
AS-Interface outputs
D0 | Guard locking |
LED function display
- The ASI LED indicates the state of the ASi bus.
- The STATE LED indicates the state of the switch.
- The LOCK/DIA LED indicates if the door is locked and whether a fault has been detected in the switch.
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | -20 … +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 4-pin |
Approach speed | 20 m/min |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Electrical connection ratings
ASi voltage | 30 V 26,5 … 31,6 V |
ASi operating current | 50 mA |
ASi auxiliary voltage | |
IEC 60742, PELV | 24 V -15% … +10% |
ASi auxiliary current | 400 mA |
ASi slave type | |
According to ASI specification 3.0 | EA code: 7 |
ID code: B | |
ASi data in | |
According to As-i Safety at Work | D0 |
D1 | |
D2 | |
D3 | |
ASi data out | |
Guard locking solenoid | D0 |
Safety class | |
EN IEC 61140 | III |
Work area
Repeat accuracy R | 10 % |
Other
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Reliability values according to EN ISO 13849-1
Performance Level | PL e |
Category | 4 |
PFHD | 4.3 x 10 -9 |
Mission time | 20 y |