ActuatorAn appropriate actuator to suit the read head selected is required. The dimensions of the actuators are the same as those of the read heads, although the former have no connection cable.
AS-Interface inputs
D0 — D3 | Switch actuated/open |
Evaluation is performed via a safety monitor.
Principle of operationReed contacts are installed in the read head of the safety system CMS. The contact blades on the reed contacts are closed under the influence of the magnetic field from the actuator. The read head only responds to the specific mating component, that is a specific actuator which is allocated to the read head type.
Dimension drawing
Design | B |
Material | |
Cable material | PUR |
Housing material | Reinforced thermoplastic (PPS), fully encapsulated |
Weight | |
Net | 0,1 kg |
Ambient temperature | -25 … 60 °C |
Degree of protection | IP67 |
Mechanical life | 100 x 106 |
Installation orientation | Any, pay attention to marking |
Reaction time | |
After change in the actuation status | max.5 ms |
Connection | Hard-wired encapsulated cable with plug connector M12 |
Cable length | 1 m |
Method of operation | Magnetic, reed contact |
Electrical connection ratings
ASi voltage | 30 V 26,5 … 31,6 V |
ASi operating current | max.30 mA |
ASi slave type | |
According to ASI specification 3.0 | ID code: B |
EA code: 0 | |
ASi data in | |
According to ASI safety at work | D0,D1,D2,D3 |
ASi LED | |
LED red | No data exchange between master and slave |
LED red/yellow alternately flashing | No data exchange between master and slave |
LED red/green alternately flashing | Fault |
LED red flashing | Fault |
LED green | Normal operation |
Work area
Switch-on distance | 7 mm |
Assured switch-off distance Sar | max.40 mm |
Center offset | 2,5 mm |
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position | |
Category | 3 |
Performance Level | PL e |
B10D | 3 x 106 |
PFHD | 4.29 x 10-8 |
Mission time | 20 y |