Alignment of read head and actuator
Operating diagram, design A
CMS-R-AZA
- Typ. switch-on distance
- Typ. switch-off distance
Design | A |
Material | |
Cable material | PVC |
Housing material | Fiber glass reinforced PPS |
Weight | |
Net | 0,055 kg |
Ambient temperature | -20 … 60 °C |
Degree of protection | IP67 |
Mechanical life | 100 x 106 |
Installation orientation | Any, pay attention to marking |
Tightening torque | 0,4 … 0,5 Nm |
Number of NO contacts | 2 NO contacts with fuse, 100 mA each and 1 NO contact with LED |
Connection | Hard-wired encapsulated cable with plug connector M12 |
Cable length | 0,2 m |
Number of LED displays | 1 LED contact status indication |
Method of operation | Magnetic, reed contact |
Electrical connection ratings
Rated conditional short-circuit current | 100 A |
Fusing | |
Power supply / safety contacts, external contact protection | Fuse 10 A gG |
Switching voltage | 24 … 35 V DC |
Contact status indication | 24 … 35 V DC |
Switching current | max.100 mA |
Contact status indication | max.15 mA |
Switching voltage according to UL | |
According to UL Class 2 | max.24 V AC/DC |
Series resistance | |
LED contact status indication | 1,5 k? |
Switching frequency, electrical | |
At I_min = 10 mA | max.5 Hz |
At nominal current 8 A | max.0,1 Hz |
Switching delay from state change | 26 ms |
Other
In compliance with | EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN ISO 14119: 2013; IEC 60947-5-3: 2013 |
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position | |
B10D | 20 x 106 |
In combination with Evaluation unit ESM-BA201, ESM-BA202, ESM-BA203, ESM-BA301, ESM-BA302, ESM-BA303, ESM-BA201P, ESM-BA301P and Actuator CMS-M-AIOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.20 mm |
Contact status indication / LED | max.15 mm |
Assured operating distance Sao | |
With center offset m=0 | min.9 mm |