Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
- DC 24 V +10% -15%
Guard locking type
CET1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
LED function display
LED rot | illuminates when the solenoid is energized |
LED grun | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The device may be operated only in conjunction with the actuator CET-A-…. The actuator must be ordered separately.
Auxiliary release
Is used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).
Dimension drawing
Block diagram
Dimension drawingBlock diagram
Technical dataApprovals
Mechanical values and environment
Housing material | |
Slide | Stainless steel |
Safety switch | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 … 55 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
X | ±5 mm |
Y | ±5 mm |
Z | ±4 mm |
Switching frequency | 1 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Electrical connection ratings
Operating voltage DC | |
LED | 24 V DC -15% … 15% Reverse polarity protected |
Current consumption | |
LED | max.6 mA |
ICM | 480 mA Solenoid |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% … +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Power consumption | |
Solenoid | 12 W |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |