Short circuit monitoring
The switch generates its own clock signal on the output lines FO1A/FO1B. Pay attention to this aspect when connecting to control systems and relays.
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN ISO 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (F01A and F01B) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Connection for control system
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | UB | Power supply, DC 24 V | BN | |
2 | FO1A | Safety output, channel 1 | WH | |
3 | 0V | Ground, DC 0 V | BU | |
4 | FO1B | Safety output, channel 2 | BK | |
5 | — | n.c. | GY |
Connection for read head
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | H1 | Data line | BN | |
3 | H2 | Data line | WH | |
4 | SH | Shield | — |
Housing material | Plastic, PBT |
Weight | |
Net | 0,096 kg |
Ambient temperature | |
Cable static | -20 … 65 °C |
Cable dynamic | -5 … 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Installation orientation | Any |
Tightening torque | max.1 Nm |
Ready delay | 1 s |
Switching frequency | max.1 Hz |
Connection | Connection cable PUR with plug connector M12 5-pin, pin 5 not used |
Electrical connection ratings
Operating voltage DC | |
UB(PELV, see operating instructions) (reverse polarity protected, regulated, residual ripple < 5%) | 24 V DC 15% … 15% |
Current consumption | max.45 mA |
Fusing | |
External (operating voltage) | 0,25 … 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
Safety outputs FO1A / FO1B | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 … 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5V … UB V DC |
LOW U(FO1A) / U(FO1B) | 0 … 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | DC-13 24V 150mA |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Work area
Repeat accuracy R | ? 10 |
Other
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.5 x 10-9 |
Mission time | 20 |
In combination with Read head CES-A-LMN-SC and Actuator CES-A-BMBOperating distance
Switch-on distance | 5 mm |
Assured switch-off distance Sar | max.10 mm |
Assured operating distance Sao | min.3,4 mm |
Switching hysteresis | min.0,05 mm |